Unit-operation capex benchmark

The whole-chain benchmark asks whether fifteen flowsheets come out at the totals their papers publish. A total can be right for the wrong reasons, so this page asks the narrower question: priced on its own, at a duty a published source also priced, is one machine right? 12 equipment items are set against an independently published cost, and every catalogue operation is checked at the point it was calibrated and then walked out to the duties real plants use.

What this page measures

Three things separate this page from the whole-chain benchmark, and all three make it harsher.

A plant total absorbs errors. Two operations wrong by the same factor in opposite directions sum to a total that looks correct, and the whole-chain page cannot see it; a per-equipment comparison has nowhere for that to hide. So the bands here are tighter: this page treats within ±25% as agreement and anything past 2.0x as a disagreement worth naming, where the whole-chain page uses 2.0x as its headline band.

A total also absorbs scope. Battery limits, wastewater, working capital, contingency and the Lang profile all sit between purchased equipment and total capital investment, and each is a place where two studies can differ legitimately. Underneath all of that is a single number - what one machine costs at one size - and that number is either right or it is not.

The catch is that almost nobody publishes it. The evidence problem below is why this page has three tiers instead of one scorecard, and why only the first tier can move the model.

The evidence problem

untangle prices purchased equipment and then applies piping, instrumentation and installation through a Lang profile. An external figure is comparable only on that scope, and only when the source also states the size the price was quoted at. That is a high bar and it is met astonishingly rarely: of the 500 open-access techno-economic analyses in this library, 3 report capital against a named piece of equipment. The rest publish totals, area subtotals or a Lang-factored plant capital, none of which can be split back into machines without inventing the split.

That count is measured, not asserted. The corpus grew from 185 papers to 500 and every one of them was searched by TEA_refs/tools/scan_per_op_capital.py, which ranks a paper on how many lines carry an equipment NAME, a PRICE and a SIZE together - the third being the one that decides whether a cost can anchor anything. Two papers came back with five or more such lines: the national-lab report already here, and one new one. Everything else in five hundred papers prices a plant, not a machine.

The scan is only trustworthy because it fails loudly. Its first version required a space inside "membrane filtration" and scored the one paper KNOWN to publish per-operation capital at rank 83 of 194 with zero hits, because a two-column PDF extracts as "Membranefiltration $2,157,464". Every space in its vocabulary is now optional, and the known positives rank first and second.

The 12 anchors below therefore come from 3 sources, and two of the three were never harvested as TEA papers at all: a national-lab design report whose appendix itemises every mechanical equipment item with its vendor, size, quote year, scaling exponent and installation factor, and a peer-reviewed engineering paper that publishes the purchased-cost build-up of one aseptic bioreactor. Both were found by hand.

Table (4 rows) - click to unfold
Source Equipment grade Anchors Median Why it qualifies
NREL/TP-5100-47764
Humbird D. et al. (2011) Process Design and Economics for Biochemical Conversion of Lignocellulosic Biomass to Ethanol. NREL/TP-5100-47764, National Renewable Energy Laboratory.
commodity bulk 6 1.15x
Appendix B gives, for every mechanical equipment item: vendor, size, quote year, scaling variable, scaling exponent, installation factor, scaled purchased cost and installed cost. It is the only per-equipment ground truth in the library, and fetch_papers.py can never harvest it - that harvester queries OpenAlex for type:article with a DOI, and a national-lab report has none.
Humbird 2021 Table 1
Humbird D. (2021) Scale-up economics for cultured meat. Biotechnology and Bioengineering 118(8):3239-3250.
pharma gmp 1 1.04x
Table 1 itemises the purchased cost build-up of one 20 m3 aseptic bioreactor and publishes the author's own bare-cost scaling exponent over 1-20 m3, so the figure can be moved to another volume on the source's own curve rather than on untangle's.
P42 - Wimble 2025 Table 4
Wimble et al. (2025) Analysis of the economic viability and environmental impacts of a conceptual process model for the recovery of lactic acid from spent media in cultivated meat production. Biotechnology Progress.
industrial biotech 5 1.14x
Table 4 breaks the 4,668,399 USD capital total into six named unit operations. It is the only paper of the 185 in TEA_refs/papers that publishes capital per unit operation.
P238 - Apple pomace biorefinery, Table 2
Apple Pomace Integrated Biorefinery for Biofuels Production: A Techno-Economic and Environmental Sustainability Analysis. Resources 13(11):156, 2024.
commodity bulk 0 not yet in the run
Table 2 is headed 'Purchase cost of the most important units' and its columns are Section | Equipment | Value | Unit | Ceq.fob ($) | Amount | Total ($). It therefore publishes, for each named machine, BOTH the size and a per-unit purchased cost - the two things an anchor needs and the two things almost no paper prints together. Found 2026-09-04 by TEA_refs/tools/scan_per_op_capital.py over the 500-paper corpus: of 313 papers scanned it and NREL/TP-5100-47764 were the only two with five or more equipment lines carrying a name, a size and a price.

Two published items are deliberately not compared. A mapping is only made when an untangle operation would genuinely be used for that duty; pairing a machine with an operation that does something else would manufacture agreement or disagreement out of the mapping rather than out of the cost model.

Table (3 rows) - click to unfold
Published item Source Published USD Why it is not compared
Molecular sieve package (9 pieces, Delta-T) NREL/TP-5100-47764
tag M-503
2,557,091 untangle has no gas-phase adsorption operation. activated_carbon is a liquid-phase polishing bed and is not the same machine, so mapping it would compare two different duties.
Product storage P42 - Wimble 2025 Table 4
Table 4
158,569 untangle does not model product storage as a unit operation; it is carried in working capital, not in the equipment list.
Beer column (Megtec, 14 ft dia x 76 ft, 32 trays) NREL/TP-5100-47764
tag D-501
3,350,232 STRUCK 2026-09-03: the duty basis cannot be verified and is probably not the column's hydraulic load. NREL scales this item on stream tag strm.a500.511 at 30,379 kg/hr. The plant makes 61 MMgal/yr of ethanol, which over 8,410 h is 27,457 L/hr - within 6% of that figure. A beer column's FEED is the fermented broth at roughly 5 wt% ethanol, so its hydraulic load is more than an order of magnitude larger; 30,379 kg/hr looks like an ethanol-rich stream, not the feed. untangle's distillation entry is a FEED-FLOW correlation, so on that reading the row priced untangle's column an order of magnitude too small against a 14 ft x 76 ft, 32-tray vessel, and it was setting the Tier 1 median. Resolving it needs NREL's Area 500 stream table, which is not in the tree (papers/ is git-ignored). Separately, a column is bought by diameter - vapour load, hence reflux ratio and relative volatility - and by stage count, neither of which a feed-flow correlation can see. Found by the 2026-09-03 chemical-engineering review.

Tier 1 - independent anchors

Each row prices the same machine at the size its source quoted. Published costs are shown both as printed and escalated to a 2026 CEPCI basis, because several of these quotes are fifteen years old and comparing them raw would flatter untangle; the ratio column uses the escalated figure. The median is 1.10x, 12 of 12 land within 2.0x, and 8 within ±25%. The spread runs from 0.69x to 1.52x.

Read that median as a floor, not an estimate. Only 2 of these 12 rows compare like scope with like. 9 compare untangle’s purchased cost against a published figure that is WIDER - either a vendor turnkey price quoted at an installation factor of one, or a paper that states it applied installation factors - and 1 against one that is narrower. Those corrections do not cancel; they run the same way on nine rows. Applying only the corrections that are arithmetically exact gives 1.10x; applying judged installation factors across the rest gives a band of 1.25x to 2.26x, central 1.71x. The published 1.10x is the number nobody has to argue about, and it is the lowest of them.

12
independent anchors
1.10x
median, CEPCI-matched
12 of 12
within 2x
31
operations at the calibration point
21.8%
median miss, designed size
Table (15 rows) - click to unfold
Operation Source Size Published At 2026 CEPCI untangle Ratio
nutsche filter
Pressure filter (Larox, 384 m2 filtration area)
NREL/TP-5100-47764
Appendix B mechanical equipment list, tag S-505
36,538 L/hr 3,519,098 5,162,366 4,135,951 0.80x
thin film evaporator
Evaporator system (wastewater concentration)
NREL/TP-5100-47764
Appendix B mechanical equipment list, tag M-640
411,178 L/hr 3,733,767 5,477,276 8,329,145 1.52x
microfiltration
Membrane bioreactor (ADI, includes membrane CIP and air scour)
NREL/TP-5100-47764
Appendix B mechanical equipment list, tag R-609
411,178 L/hr 5,155,780 7,563,308 9,394,536 1.24x
reverse osmosis
Reverse osmosis system (ADI)
NREL/TP-5100-47764
Appendix B mechanical equipment list, tag S-610
411,178 L/hr 2,171,816 3,185,961 3,382,077 1.06x
centrifugation disc
Centrifuge (wastewater sludge dewatering)
NREL/TP-5100-47764
Appendix B mechanical equipment list, tag S-611
411,178 L/hr 6,378,482 9,356,960 13,289,490 1.42x
stirred tank bioreactor
Aerobic cellulase fermenter, 80,000 gal (302.8 m3) - vessel F-400 plus agitator A-400 plus a ninth share of the M-401 air package
NREL/TP-5100-47764
Appendix B mechanical equipment list, Area 400, tags F-400 / A-400 / M-401
48,000 L 319,613 494,821 520,904 1.05x
stirred tank bioreactor
Aseptic 316L stirred-tank bioreactor, 20 m3, ASME BPE-2016
Humbird 2021 Table 1
Table 1, purchased cost build-up
48,000 L 1,035,609 1,387,452 1,446,957 1.04x
microfiltration
Membrane filtration
P42 - Wimble 2025 Table 4
Table 4, Overview of capital costs for lactic acid recovery and purification
56,196 L/hr 2,157,464 2,184,774 2,887,579 1.32x
activated carbon
Activated carbon beds
P42 - Wimble 2025 Table 4
Table 4, Overview of capital costs for lactic acid recovery and purification
50,576 L/hr 293,017 296,726 351,889 1.19x
ion exchange anion
Ion exchange
P42 - Wimble 2025 Table 4
Table 4, Overview of capital costs for lactic acid recovery and purification
50,572 L/hr 241,155 244,208 236,173 0.97x
reverse osmosis
NF / RO skid
P42 - Wimble 2025 Table 4
Table 4, Overview of capital costs for lactic acid recovery and purification
28,378 L/hr 1,018,552 1,031,445 716,292 0.69x
thin film evaporator
Multi-effect evaporator
P42 - Wimble 2025 Table 4
Table 4, Overview of capital costs for lactic acid recovery and purification
1,752 L/hr 799,641 809,763 923,730 1.14x
stirred tank bioreactor
Fermenter (ethanol fermentation, 12 off)
P238 - Apple pomace biorefinery, Table 2
Table 2, Purchase cost of the most important units, Fermentation section
711,100 L 673,465 0 3,572,429 not yet in the run
stirred tank bioreactor
Seed reactor 3 (1 off)
P238 - Apple pomace biorefinery, Table 2
Table 2, Purchase cost of the most important units, Fermentation section
407,900 L 384,188 0 2,093,202 not yet in the run
stirred tank bioreactor
Seed reactor 1 (3 off)
P238 - Apple pomace biorefinery, Table 2
Table 2, Purchase cost of the most important units, Fermentation section
27,200 L 73,668 0 360,098 not yet in the run
Scope and comparison basis, per row
  • nutsche filter — purchased excludes auxiliaries scope. flow basis at the source's own scaled duty
  • thin film evaporator — purchased includes installation scope. flow basis at the source's own scaled duty
  • microfiltration — purchased includes installation scope. flow basis at the source's own scaled duty
  • reverse osmosis — purchased includes installation scope. flow basis at the source's own scaled duty
  • centrifugation disc — purchased includes installation scope. flow basis at the source's own scaled duty
  • stirred tank bioreactor — purchased scope. source publishes no exponent for this item, so it is scaled on untangle's own 0.65. That exponent sits at the low end of the vessel band, which raises the scaled-down published figure and so FLATTERS untangle on this row
  • stirred tank bioreactor — purchased scope. vessel basis, both sides at 48,000 L
  • microfiltration — installed scope. priced inside the corpus replication of the paper (flow basis)
  • activated carbon — installed scope. priced inside the corpus replication of the paper (bed_volume basis)
  • ion exchange anion — installed scope. priced inside the corpus replication of the paper (bed_volume basis)
  • reverse osmosis — installed scope. priced inside the corpus replication of the paper (flow basis)
  • thin film evaporator — installed scope. priced inside the corpus replication of the paper (flow basis)
  • stirred tank bioreactor — purchased scope. vessel basis, both sides at 711,100 L
  • stirred tank bioreactor — purchased scope. vessel basis, both sides at 407,900 L
  • stirred tank bioreactor — purchased scope. vessel basis, both sides at 27,200 L
Published purchased cost against untangle, per equipment item (2026 CEPCI, log-log)
10k 10k 100k 100k 1M 1M 10M 10M 100M 100M stirred tank bioreactor (1): paper 1.387M USD, untangle 1.447M USD (1.04x). Humbird 2021 Table 1, vessel basis, both sides at 48,000 L. Click to jump to its row above. 1 stirred tank bioreactor (2): paper 494.821k USD, untangle 520.904k USD (1.05x). NREL/TP-5100-47764, source publishes no exponent for this item, so it is scaled on untangle's own 0.65. That exponent sits at the low end of the vessel band, which raises the scaled-down published figure and so FLATTERS untangle on this row. Click to jump to its row above. 2 thin film evaporator (3): paper 5.477M USD, untangle 8.329M USD (1.52x). NREL/TP-5100-47764, flow basis at the source's own scaled duty. Click to jump to its row above. 3 microfiltration (4): paper 7.563M USD, untangle 9.395M USD (1.24x). NREL/TP-5100-47764, flow basis at the source's own scaled duty. Click to jump to its row above. 4 nutsche filter (5): paper 5.162M USD, untangle 4.136M USD (0.80x). NREL/TP-5100-47764, flow basis at the source's own scaled duty. Click to jump to its row above. 5 reverse osmosis (6): paper 3.186M USD, untangle 3.382M USD (1.06x). NREL/TP-5100-47764, flow basis at the source's own scaled duty. Click to jump to its row above. 6 centrifugation disc (7): paper 9.357M USD, untangle 13.289M USD (1.42x). NREL/TP-5100-47764, flow basis at the source's own scaled duty. Click to jump to its row above. 7 stirred tank bioreactor (8): paper 673.465k USD, untangle 3.572M USD (5.30x). P238 - Apple pomace biorefinery, Table 2, vessel basis, both sides at 711,100 L. Click to jump to its row above. 8 stirred tank bioreactor (9): paper 384.188k USD, untangle 2.093M USD (5.45x). P238 - Apple pomace biorefinery, Table 2, vessel basis, both sides at 407,900 L. Click to jump to its row above. 9 stirred tank bioreactor (10): paper 73.668k USD, untangle 360.098k USD (4.89x). P238 - Apple pomace biorefinery, Table 2, vessel basis, both sides at 27,200 L. Click to jump to its row above. 10 activated carbon (11): paper 296.726k USD, untangle 351.889k USD (1.19x). P42 - Wimble 2025 Table 4, priced inside the corpus replication of the paper (bed_volume basis). Click to jump to its row above. 11 thin film evaporator (12): paper 809.763k USD, untangle 923.73k USD (1.14x). P42 - Wimble 2025 Table 4, priced inside the corpus replication of the paper (flow basis). Click to jump to its row above. 12 ion exchange anion (13): paper 244.208k USD, untangle 236.173k USD (0.97x). P42 - Wimble 2025 Table 4, priced inside the corpus replication of the paper (bed_volume basis). Click to jump to its row above. 13 microfiltration (14): paper 2.185M USD, untangle 2.888M USD (1.32x). P42 - Wimble 2025 Table 4, priced inside the corpus replication of the paper (flow basis). Click to jump to its row above. 14 reverse osmosis (15): paper 1.031M USD, untangle 716.292k USD (0.69x). P42 - Wimble 2025 Table 4, priced inside the corpus replication of the paper (flow basis). Click to jump to its row above. 15 published, 2026 CEPCI (USD) untangle (USD)

1 stirred tank bioreactor · 2 stirred tank bioreactor · 3 thin film evaporator · 4 microfiltration · 5 nutsche filter · 6 reverse osmosis · 7 centrifugation disc · 8 stirred tank bioreactor · 9 stirred tank bioreactor · 10 stirred tank bioreactor · 11 activated carbon · 12 thin film evaporator · 13 ion exchange anion · 14 microfiltration · 15 reverse osmosis. A filled marker is a like-for-like purchased-cost scope; a hollow marker is one where the source publishes a wider scope, which makes that ratio conservative.

Read down the ratio column and the pattern is not scatter, but it is not raw duty either: a bed-sized column at fifty cubic metres an hour agrees while a flow-sized membrane at the same duty does not. The split that does separate the rows is whether untangle bought one machine or a parallel train. The 9 rows served by a single unit have a median of 1.14x; the 3 served by parallel trains have a median of 0.97x, and the largest train on the page is 4 units.

Both bioreactor rows land inside ±5% - and they come from two different authors, at opposite ends of the grade ladder, on a vessel basis where both sides describe the same 48 m3 tank. 4 of the 5 rows from the one paper that publishes per-operation capital agree within ±31%, at duties between 1,752 and 56,196 L/hr. The rows that miss badly are all at commodity throughput: the national-lab wastewater train runs at 411 m3/hr, which is more than two orders of magnitude past the 1,000 L/hr point every catalogue entry is anchored at.

Microfiltration is the clearest single signal on the page. It is the one operation that 2 independent anchors both disagree with, in the same direction, at a median of 1.28x and a worst case of 1.32x - and both of those rows apply it at 41.1x its single-unit ceiling of 10,000 L/hr. That is the same defect the whole-chain benchmark records against its lactic-acid case, arrived at from a completely different direction.

Tier 2 - the calibration point

Tier 1 is short because the evidence is short. Tier 2 is the opposite: every catalogue operation, 31 of them, priced through the full thorough-mode path at 1,000 L/hr and compared to the anchor in its own database entry. All 31 sit inside the 50% house rule that backend/tests/test_capex_vs_published.py enforces on every commit, with 0 exceptions.

That statement is worth much less than it looks, and the split below is the reason. For an operation whose price comes straight off its database anchor, agreement is true by construction: the row proves the scaling law, the id mapping and the multi-unit rule have not drifted, and it proves nothing whatever about accuracy. It is a regression guard. Only the designed-size operations - membranes sized on computed area, bind-elute columns sized on computed bed volume - are a real test, because there an independent size correlation has to land back on the anchor without being told to.

10 operations are sized from a physical quantity the simulation computes. Their median miss is 21.8% and the worst is 40.0%. This is the informative half of Tier 2.

Table (10 rows) - click to unfold
Operation Anchor grade Anchor untangle Miss Anchor note
microfiltration food grade 260,870 365,340 +40.0%
2026 re-anchor, crossflow MF skid @1000 L/hr
reverse osmosis chemical 90,000 122,845 +36.5%
2026 re-anchor, RO learning-curve data
hydrophobic interaction chromatography pharma gmp 700,000 517,100 -26.1%
2026 re-anchor, HIC system
ion exchange cation pharma gmp 700,000 517,100 -26.1%
2026 re-anchor, GMP IEX system @1000 L/hr
size exclusion pharma gmp 650,000 795,777 +22.4%
2026 re-anchor; DB-priced (load-volume bed)
affinity chromatography pharma gmp 800,000 631,028 -21.1%
2026 re-anchor, protein-A class system
reverse phase pharma gmp 650,000 517,100 -20.4%
2026 re-anchor, prep RP system
ultrafiltration 10k food grade 391,304 409,683 +4.7%
2026 re-anchor, TFF skid @1000 L/hr
nanofiltration food grade 278,261 290,731 +4.5%
corrected 2026-08-19, ~4.0k USD/m2 parity with UF
depth filtration food grade 104,348 104,304 +0.0%
2026 re-anchor, pod holder + skid @1000 L/hr

21 operations are priced directly off their anchor. Their median miss is 0.0%, which is CEPCI rounding and the multi-unit rule, not a measurement. These rows are here so that a future change to the scaling law, the id mapping or the grade ladder shows up as a number that moved.

Table (21 rows) - click to unfold
Operation Anchor grade Anchor untangle Miss Anchor note
centrifugation disc pharma gmp 650,000 936,326 +44.1%
2026 re-anchor, disc-stack vendor data
freeze drying pharma gmp 2,000,000 1,449,235 -27.5%
one ~100 m2 lyophilizer, ~25 L/hr of fill
vacuum tray drying chemical 880,000 749,179 -14.9%
one vacuum tray dryer published @max 200 L/hr
ultrafiltration 100k food grade 391,304 440,530 +12.6%
existing 100 kDa cassette on the 2026 TFF skid @1000 L/hr
nutsche filter chemical 350,000 373,861 +6.8%
2026 re-anchor, agitated nutsche
activated carbon chemical 100,000 100,000 +0.0%
2026 re-anchor, GAC contactor system
air lift fermentor industrial biotech 666,000 666,000 +0.0%
STR x0.8, no agitator gearbox
basket centrifuge chemical 500,000 500,000 +0.0%
2026 re-anchor, batch basket
continuous bioreactor industrial biotech 915,000 915,000 +0.0%
STR x1.1 continuous premium
continuous heat sterilizer chemical 250,000 250,000 +0.0%
2026 re-anchor, HTST skid
crystallization chemical 400,000 400,000 +0.0%
2026 re-anchor, Towler class, CEPCI-escalated
electrodialysis chemical 600,000 600,000 +0.0%
2026 re-anchor, ED stack cost data
fed batch bioreactor industrial biotech 1,065,000 1,065,000 +0.0%
STR x1.28 feed system premium
flocculation chemical 90,000 90,000 +0.0%
2026 re-anchor, agitated floc tank system
fluid bed dryer chemical 500,000 500,000 +0.0%
2026 re-anchor, GEA/Glatt class
liquid liquid extraction chemical 350,000 350,000 +0.0%
2026 re-anchor, mixer-settler train
mixing vessel food grade 160,000 160,000 +0.0%
2026 re-anchor, instrumented blend system
precipitation chemical 300,000 300,000 +0.0%
2026 re-anchor, reactor + dosing system
spray drying pharma gmp 600,000 600,000 +0.0%
2026 re-anchor, vendor data
stirred tank bioreactor industrial biotech 832,000 832,000 +0.0%
NREL D1 + Humbird 2021, purchased scope
viral inactivation pharma gmp 180,000 180,000 +0.0%
2026 re-anchor, low-pH hold system

Tier 3 - what scale does to both curves

Tier 2 pins every operation at exactly one duty. Real cases apply them one to three orders of magnitude away from it, and the whole-chain benchmark's largest open capital error is an operation being read 41.1x past its ceiling. So this tier takes each Tier 1 source's own published correlation - the source's exponent, the source's quoted point - and walks both curves across the range.

Two numbers frame every table below. At the 5 points where the source actually quoted a price, rather than extrapolating one, the median ratio is 1.24x. At the 1,000 L/hr calibration point, where untangle is the one not extrapolating, it is 0.94x. Neither curve is evidence away from its own anchor, and the tables mark which point is which.

Below each entry's single-unit ceiling the median ratio is 1.01x. Above it, where untangle stops buying one machine and starts buying parallel trains, it is 0.97x. The mechanism is visible in the trains column: the sources scale one machine indefinitely and untangle does not, so the two curves are guaranteed to separate, and the only question is whether the separation is physical. In the worst case on this page untangle buys 38 parallel nutsche filter units to serve 411,178 L/hr against a ceiling of 10,000 L/hr, which no engineer would specify.

thin film evaporator · NREL/TP-5100-47764

Evaporator system (wastewater concentration). Single-unit ceiling 393,100 L/hr.

Table (9 rows) - click to unfold
Duty L/hr Source correlation untangle Ratio Trains
1,000 147,961 225,000 1.52x 1
2,500 256,396 389,894 1.52x 1
5,000 388,623 590,969 1.52x 1
10,000 589,043 895,741 1.52x 1
25,000 1,020,730 1,552,196 1.52x 1
50,000 1,547,137 2,352,689 1.52x 1
100,000 2,345,021 3,566,010 1.52x 1
200,000 3,554,387 5,405,060 1.52x 1
411,178 5,477,276 8,329,145 1.52x 1 source’s quoted point

microfiltration · NREL/TP-5100-47764

Membrane bioreactor (ADI, includes membrane CIP and air scour). Single-unit ceiling 393,100 L/hr.

Table (9 rows) - click to unfold
Duty L/hr Source correlation untangle Ratio Trains
1,000 204,312 187,826 0.92x 1
2,500 354,045 340,735 0.96x 1
5,000 536,631 534,671 1.00x 1
10,000 813,381 838,988 1.03x 1
25,000 1,409,477 1,522,008 1.08x 1
50,000 2,136,367 2,388,286 1.12x 1
100,000 3,238,127 3,747,623 1.16x 1
200,000 4,908,083 5,880,651 1.20x 1
411,178 7,563,308 9,394,536 1.24x 1 source’s quoted point

nutsche filter · NREL/TP-5100-47764

Pressure filter (Larox, 384 m2 filtration area). Single-unit ceiling 10,000 L/hr.

Table (10 rows) - click to unfold
Duty L/hr Source correlation untangle Ratio Trains
1,000 290,170 315,000 1.09x 1
2,500 603,956 545,852 0.90x 1
5,000 1,051,548 827,356 0.79x 1
10,000 1,830,851 1,254,038 0.69x 1
25,000 3,810,702 3,021,419 0.79x 3 past the 10,000 L/hr ceiling
36,538 5,162,366 4,135,951 0.80x 4 source’s quoted point
50,000 6,634,817 5,338,061 0.81x 5 past the 10,000 L/hr ceiling
100,000 11,551,888 9,961,175 0.86x 10 past the 10,000 L/hr ceiling
200,000 20,113,005 18,304,363 0.91x 19 past the 10,000 L/hr ceiling
411,178 35,799,492 34,726,703 0.97x 38 past the 10,000 L/hr ceiling

reverse osmosis · NREL/TP-5100-47764

Reverse osmosis system (ADI). Single-unit ceiling 393,100 L/hr.

Table (9 rows) - click to unfold
Duty L/hr Source correlation untangle Ratio Trains
1,000 86,064 81,000 0.94x 1
2,500 149,137 142,958 0.96x 1
5,000 226,050 219,708 0.97x 1
10,000 342,628 337,664 0.99x 1
25,000 593,727 595,947 1.00x 1
50,000 899,921 915,897 1.02x 1
100,000 1,364,026 1,407,619 1.03x 1
200,000 2,067,476 2,163,334 1.05x 1
411,178 3,185,961 3,382,077 1.06x 1 source’s quoted point

centrifugation disc · NREL/TP-5100-47764

Centrifuge (wastewater sludge dewatering). Single-unit ceiling 150,000 L/hr.

Table (9 rows) - click to unfold
Duty L/hr Source correlation untangle Ratio Trains
1,000 252,765 234,000 0.93x 1
2,500 438,007 412,989 0.94x 1
5,000 663,894 634,713 0.96x 1
10,000 1,006,275 975,474 0.97x 1
25,000 1,743,736 1,721,625 0.99x 1
50,000 2,643,010 2,645,923 1.00x 1
100,000 4,006,054 4,066,454 1.01x 1
200,000 6,072,043 7,588,271 1.25x 2 past the 150,000 L/hr ceiling
411,178 9,356,960 13,289,490 1.42x 3 source’s quoted point

Every ceiling in the model, with the duty its anchor was quoted at. The headroom column is the ratio between them: how far an operation can be scaled before the multi-unit rule takes over from the exponent. It spans 1.0x to 150.0x, median 5.0x, and 8 operations reach their ceiling at no more than twice the duty they were anchored at - which means that for those, almost every real use is on the parallel-train branch rather than the scaling branch.

Table (31 rows) - click to unfold
Operation Category Anchor grade Anchor USD Anchored at L/hr Exponent Ceiling L/hr Headroom Tier 2 class
freeze drying drying pharma gmp 2,000,000 25 0.5 25 1.0x database priced
reverse phase purification pharma gmp 650,000 1,000 0.65 1,000 1.0x designed size
vacuum tray drying drying chemical 880,000 200 0.55 200 1.0x database priced
basket centrifuge clarification chemical 500,000 1,000 0.65 2,000 2.0x database priced
fluid bed dryer drying chemical 500,000 1,000 0.6 2,000 2.0x database priced
hydrophobic interaction chromatography purification pharma gmp 700,000 1,000 0.65 2,000 2.0x designed size
nanofiltration purification food grade 278,261 1,000 0.7 2,000 2.0x designed size
size exclusion polishing pharma gmp 650,000 1,000 0.6 2,000 2.0x designed size
affinity chromatography purification pharma gmp 800,000 1,000 0.6 5,000 5.0x designed size
air lift fermentor upstream industrial biotech 666,000 1,000 0.65 5,000 5.0x database priced
continuous bioreactor upstream industrial biotech 915,000 1,000 0.65 5,000 5.0x database priced
depth filtration clarification food grade 104,348 1,000 0.6 5,000 5.0x designed size
electrodialysis purification chemical 600,000 1,000 0.75 5,000 5.0x database priced
fed batch bioreactor upstream industrial biotech 1,065,000 1,000 0.65 5,000 5.0x database priced
stirred tank bioreactor upstream industrial biotech 832,000 1,000 0.65 5,000 5.0x database priced
ultrafiltration 100k purification food grade 391,304 1,000 0.7 5,000 5.0x database priced
ultrafiltration 10k purification food grade 391,304 1,000 0.7 5,000 5.0x designed size
activated carbon polishing chemical 100,000 1,000 0.6 10,000 10.0x database priced
ion exchange cation purification pharma gmp 700,000 1,000 0.75 10,000 10.0x designed size
microfiltration clarification food grade 260,870 1,000 0.65 10,000 10.0x designed size
nutsche filter clarification chemical 350,000 1,000 0.6 10,000 10.0x database priced
viral inactivation polishing pharma gmp 180,000 1,000 0.55 10,000 10.0x database priced
crystallization purification chemical 400,000 1,000 0.65 20,000 20.0x database priced
liquid liquid extraction purification chemical 350,000 1,000 0.6 20,000 20.0x database priced
reverse osmosis purification chemical 90,000 1,000 0.62 20,000 20.0x designed size
continuous heat sterilizer upstream chemical 250,000 1,000 0.55 50,000 50.0x database priced
precipitation clarification chemical 300,000 1,000 0.6 50,000 50.0x database priced
flocculation clarification chemical 90,000 1,000 0.6 100,000 100.0x database priced
mixing vessel preparation food grade 160,000 1,000 0.6 100,000 100.0x database priced
spray drying drying pharma gmp 600,000 1,000 0.6 100,000 100.0x database priced
centrifugation disc clarification pharma gmp 650,000 1,000 0.62 150,000 150.0x database priced

Where each gap comes from

A ratio says a machine is priced wrong. It does not say which of the model's three knobs is wrong, and those knobs have entirely different evidence behind them and entirely different consequences. Every Tier 1 flow-based gap splits into three terms exactly - the split below is an identity, not a regression, and the build fails if the three do not re-multiply to the measured ratio.

First, how much of each row is evidence at all. NREL publishes both the size the vendor quoted and the size the report scaled that quote to, and the second column of its appendix was being read while the first was thrown away. It matters: where the two agree, the price is a vendor quote at the duty being compared, so one package covers this duty is a procurement fact and the ceiling it implies is real. Where they disagree the report is extrapolating on its own exponent and the row says nothing about what size can be bought.

4 of the 5 rows are quoted within 10% of the duty used. Across the whole appendix it is 93 of 144 items.

Table (5 rows) - click to unfold
Operation Item Vendor quoted at L/hr Report uses at L/hr Scale ratio
nutsche filter
Pressure filter (Larox, 384 m2 filtration area)
31,815 36,538 1.15x the report extrapolated: not evidence of procurable size
thin film evaporator
Evaporator system (wastewater concentration)
393,100 411,178 1.05x quoted at the duty compared: a procurement fact
microfiltration
Membrane bioreactor (ADI, includes membrane CIP and air scour)
393,100 411,178 1.05x quoted at the duty compared: a procurement fact
reverse osmosis
Reverse osmosis system (ADI)
393,100 411,178 1.05x quoted at the duty compared: a procurement fact
centrifugation disc
Centrifuge (wastewater sludge dewatering)
393,100 411,178 1.05x quoted at the duty compared: a procurement fact

Now the split. LEVEL is the anchor price with the scale argument removed from both sides - untangle at its 1000 L/hr reference over the source's price carried back to 1000 L/hr on the source's exponent. EXPONENT is (duty/1000)^(e_untangle - e_source), pure disagreement about the economy of scale compounded over the whole span. TRAINS is the surcharge for buying parallel machines rather than one.

Read the three terms as a diagnostic, not as three measurements. LEVEL is defined through the source's exponent, and on these rows that exponent never acted: the vendor quoted at the duty used, so any error in it transfers one-for-one into LEVEL. Only the PRODUCT of the first two terms is measured - untangle's single-machine price at the source's own quoted duty, over the source's price there. That product averages 1.02x. The trains term, 1.16x, is the second and independent measurement. The corrected reading of this table is therefore two numbers, not three.

What survives is the direction. The level term averages 1.06x and 4 of 5 rows sit within ±25% of parity, so nothing here indicts the anchor prices; and the trains term is the largest single mechanism on the page. A row at 3x is not a mispriced machine, it is a correctly priced machine bought too many times.

Table (5 rows) - click to unfold
Operation Scale span Exponent u/src Trains Level Exponent Trains term Total
thin film evaporator 411x 0.60 / 0.60 1 1.52x 1.00x 1.00x 1.52x
centrifugation disc 411x 0.62 / 0.60 3 0.93x 1.13x 1.36x 1.42x
microfiltration 411x 0.65 / 0.60 1 0.92x 1.35x 1.00x 1.24x
reverse osmosis 411x 0.62 / 0.60 1 0.94x 1.13x 1.00x 1.06x
nutsche filter 36x 0.60 / 0.80 4 1.09x 0.49x 1.52x 0.80x

The exponents themselves, as the source publishes them. This is the only per-equipment-class exponent table in the library that comes from a costing study rather than a textbook, so it is what untangle's own exponents can be set against. Median across all 144 items is 0.70.

Read it with the scale-ratio column. An item quoted at the size it is used at never exercised its exponent, so these are the report's stated conventions rather than exponents fitted from repeated quotes - a literature datum of the same kind as Towler or Peters, not a measurement. And note that adopting them means lowering untangle's, which runs against the house rule that holds exponents at the high end of their band so scale-up errs expensive. That rule is a deliberate choice, not an oversight; what the next section measures is what it costs.

Table (9 rows) - click to unfold
Equipment kind Items Exponent median Range Installation factor Median scale ratio
pumps 38 0.80 0.60 - 0.80 2.3 1.04x
tanks and vessels 29 0.70 0.60 - 0.70 2.0 1.05x
packaged systems 23 0.60 0.00 - 0.60 1.7 1.05x
agitators 22 0.50 0.50 - 1.00 1.5 1.05x
reactors and fermenters 10 0.85 0.70 - 1.00 1.8 1.00x
heat exchangers 8 0.70 0.60 - 1.00 2.2 1.02x
conveyors 6 0.60 0.60 - 0.80 1.7 1.10x
separators and filters 5 0.60 0.60 - 0.80 1.7 1.05x
distillation columns 1 0.60 0.60 - 0.60 2.4 0.96x

One reading of the scale table is that untangle's curve should simply be fitted to the source's. It is worth taking seriously, and it fails for a specific reason.

Fit the exponent so untangle passes exactly through the point the source actually quoted - one free parameter, anchored at untangle's own reference - and ask whether the answer is a number anyone has published for that equipment class. On 4 of 5 operations it is not.

That is the argument against fitting, in one table. An exponent is a physical claim about how one machine's cost grows, and its band is set by what the machine is made of: a membrane plant is element count, near-linear; a column is diameter squared; a vessel is the six-tenths shell plus a drive that scales faster. If the only exponent that reaches the published point lies outside that band, the disagreement is not in the exponent - it is in the level, the scope or the grade - and fitting it anyway would launder a level error into a scaling law, which then makes every OTHER duty wrong. The one operation whose two-point fit lands inside its band is the one place this evidence could honestly move a curve.

Table (5 rows) - click to unfold
Operation Exponent now Exponent a two-point fit demands Published band
thin film evaporator 0.60 0.530 0.55 - 0.70 below the published band
reverse osmosis 0.62 0.610 0.70 - 0.85 below the published band
centrifugation disc 0.62 0.613 0.60 - 0.70 inside the published band
microfiltration 0.65 0.614 0.70 - 0.85 below the published band
nutsche filter 0.60 0.777 0.55 - 0.70 above the published band

What it is worth to the whole-chain benchmark

The obvious next question is whether adopting the source's exponents and its single-package ceilings would make the whole-chain benchmark agree better with its papers. It is measurable, so here it is measured - on that page's own statistics, each scenario applied in memory with no price touched, and every change in correlation carrying a paired bootstrap interval over 20,000 resamples of the same cases.

The answer is no.

Ceilings. The vendor-quoted package size is now shipped for the non-sanitary grades, so this scenario probes what is left: extending it to the sanitary grades as well, where the CIP-coverage argument says it should not go. Correlation on capital moves by under 0.001 either way - nothing, which is the answer that argument predicts.

The exponents no longer buy anything. On the cases every scenario can be paired on, capital correlation goes from 0.115 to 0.114, a change of -0.001 with a 95% interval of [-0.006, 0.005], which contains zero. The share within 2x goes from 14% to 14%, the median from 0.47x to 0.46x and the median spread from 3.53x to 3.53x. The 2026-09-05 measurement found a gain of about one hundredth in r here; on the current engine it is gone. The cost model has moved a long way since, with evaporator and column trains among other lines now priced on their own design, and this page does not attribute the change to any one of those moves.

Both together is the same as the exponents alone, at 0.114. Across all 4 scenarios and all three measures, 0 changes in correlation clear their own confidence interval, and that includes the least-squares price fit on the last row, the largest move on the table.

The reason is a duty mismatch, and it is the most important structural fact these two pages have produced between them. The fifteen flowsheet cases run between one and roughly a hundred times the catalogue reference. The independent anchors sit at 411 m3/hr, four hundred times it. The exponent gap and the ceiling both do their damage beyond where the benchmark cases live, so the per-equipment evidence and the whole-chain scorecard are not two views of one problem. Each has to be fixed on its own terms, and neither validates the other.

Table (15 rows) - click to unfold
Measure Scenario n Median Within 2x Spread r (log) Change in r [95% CI]
TCI baseline 8 0.70x 12% 3.84x 0.482
Vendor ceilings 7 0.47x 14% 3.53x 0.115 +0.000 [+0.000, +0.000]
Source exponents 7 0.46x 14% 3.53x 0.114 -0.001 [-0.006, +0.005]
Both together 7 0.46x 14% 3.53x 0.114 -0.001 [-0.006, +0.005]
Fitted prices (contrast) 7 0.67x 43% 3.17x 0.297 +0.182 [-0.073, +0.553]
OPEX baseline 6 0.67x 67% 1.76x 0.434
Vendor ceilings 6 0.67x 67% 1.76x 0.434 +0.000 [+0.000, +0.000]
Source exponents 6 0.67x 67% 1.76x 0.434 -0.000 [-0.004, +0.001]
Both together 6 0.67x 67% 1.76x 0.434 -0.000 [-0.004, +0.001]
Fitted prices (contrast) 6 0.68x 83% 1.70x 0.494 +0.060 [-0.033, +0.264]
COGS baseline 7 0.52x 43% 2.14x 0.965
Vendor ceilings 7 0.52x 43% 2.14x 0.965 +0.000 [+0.000, +0.000]
Source exponents 7 0.52x 43% 2.15x 0.965 -0.000 [-0.002, +0.000]
Both together 7 0.52x 43% 2.15x 0.965 -0.000 [-0.002, +0.000]
Fitted prices (contrast) 7 0.54x 43% 2.13x 0.969 +0.004 [-0.001, +0.156]

What the numbers say

1. At the size it was calibrated for, the cost model is good. Where a published source and untangle both sit near their own anchor, agreement is inside ±25% across different authors, different equipment classes and a fifteen-year span of quote years. That is a stronger result than the whole-chain page can show, because there is no Lang factor, no battery-limit convention and no wastewater scope in between.

2. The error tracks the multi-unit rule, not the equipment class. Split Tier 1 by whether untangle bought one machine or several and the medians are 1.14x against 0.97x. Equipment class does not sort the rows and neither does the source; a single-scale calibration read far from its anchor does.

3. The parallel-train rule is where it becomes visible. Past the single-unit ceiling capital goes close to linear in flow, and the per-operation exponent stops doing any work. Several ceilings are low enough that this is the normal case rather than the exception, and at least one produces a unit count no engineer would specify.

4. Membranes at commodity scale are the largest single gap. Two independent sources, one national-lab and one peer-reviewed, disagree with the membrane anchor in the same direction at high duty. This is the same defect the whole-chain benchmark finds in its lactic-acid case; two methods reaching one conclusion is the strongest evidence on either page.

What this cannot claim

It is 12 anchors, and they are not a sample. They are every per-equipment figure in the library that could be traced to a size and a scope. They over- represent commodity wastewater duty, because that is what the one national-lab report with an itemised equipment list happens to build, and they contain no chromatography at all.

Scope is not perfectly matched on every row. Several national-lab items are quoted with an installation factor of one because the vendor price already includes installation, and the per-operation paper's figures are most likely installed rather than purchased. Both make untangle look worse than a like-for-like comparison would, so those ratios are conservative - and they are marked, not silently mixed in.

Grade is a real difference, not only an error. A sanitary bioprocess skid and a commodity wastewater package are not the same machine. Each row is priced at the grade its source was quoted at, which is the most that can be done about it, but some of every remaining gap is legitimately grade rather than calibration.

Tier 3 compares two extrapolations. Away from its own quoted point, a source's correlation is a projection, exactly as untangle's is. The tables mark the one point per curve that is a measurement. Read the rest as showing where and why two models diverge, not as showing which is right.

Tier 2 is not accuracy. 21 of its 31 rows compare the model to the number it was built from. They are on the page because a benchmark that quietly counted them as agreement would be reporting its own inputs back to itself.

Reproduce it

Both steps are in the repository. The harness re-prices every anchor against the working tree; the builder turns the resulting CSVs into this page. A guard test in the backend suite fails when the two disagree, so a stale page cannot be committed.

cd backend && python ../TEA_refs/tools/run_unit_op_benchmark.py
cd backend && python ../TEA_refs/tools/build_benchmark2_page.py

The anchor set, with a locator and a quote for every published figure, is TEA_refs/data/unit_op_anchors.json. The measured rows are unit_op_capex_benchmark.csv, unit_op_capex_sweep.csv and unit_op_capex_ceilings.csv in the same directory. The whole-chain benchmark this page complements is at benchmark.html.