Three things separate this page from the whole-chain benchmark, and all three make it harsher.
A plant total absorbs errors. Two operations wrong by the same factor in opposite directions sum to a total that looks correct, and the whole-chain page cannot see it; a per-equipment comparison has nowhere for that to hide. So the bands here are tighter: this page treats within ±25% as agreement and anything past 2.0x as a disagreement worth naming, where the whole-chain page uses 2.0x as its headline band.
A total also absorbs scope. Battery limits, wastewater, working capital, contingency and the Lang profile all sit between purchased equipment and total capital investment, and each is a place where two studies can differ legitimately. Underneath all of that is a single number - what one machine costs at one size - and that number is either right or it is not.
The catch is that almost nobody publishes it. The evidence problem below is why this page has three tiers instead of one scorecard, and why only the first tier can move the model.
untangle prices purchased equipment and then applies piping, instrumentation and installation through a Lang profile. An external figure is comparable only on that scope, and only when the source also states the size the price was quoted at. That is a high bar and it is met astonishingly rarely: of the 500 open-access techno-economic analyses in this library, 3 report capital against a named piece of equipment. The rest publish totals, area subtotals or a Lang-factored plant capital, none of which can be split back into machines without inventing the split.
That count is measured, not asserted. The corpus grew from 185 papers to
500 and every one of them was searched by
TEA_refs/tools/scan_per_op_capital.py, which ranks a paper on how many lines
carry an equipment NAME, a PRICE and a SIZE together - the third being the one that decides
whether a cost can anchor anything. Two papers came back with five or more such lines: the
national-lab report already here, and one new one. Everything else in five hundred papers
prices a plant, not a machine.
The scan is only trustworthy because it fails loudly. Its first version required a space inside "membrane filtration" and scored the one paper KNOWN to publish per-operation capital at rank 83 of 194 with zero hits, because a two-column PDF extracts as "Membranefiltration $2,157,464". Every space in its vocabulary is now optional, and the known positives rank first and second.
The 12 anchors below therefore come from 3 sources, and two of the three were never harvested as TEA papers at all: a national-lab design report whose appendix itemises every mechanical equipment item with its vendor, size, quote year, scaling exponent and installation factor, and a peer-reviewed engineering paper that publishes the purchased-cost build-up of one aseptic bioreactor. Both were found by hand.
| Source | Equipment grade | Anchors | Median | Why it qualifies |
|---|---|---|---|---|
| NREL/TP-5100-47764 Humbird D. et al. (2011) Process Design and Economics for Biochemical Conversion of Lignocellulosic Biomass to Ethanol. NREL/TP-5100-47764, National Renewable Energy Laboratory. |
commodity bulk | 6 | 1.15x | Appendix B gives, for every mechanical equipment item: vendor, size, quote year, scaling variable, scaling exponent, installation factor, scaled purchased cost and installed cost. It is the only per-equipment ground truth in the library, and fetch_papers.py can never harvest it - that harvester queries OpenAlex for type:article with a DOI, and a national-lab report has none. |
| Humbird 2021 Table 1 Humbird D. (2021) Scale-up economics for cultured meat. Biotechnology and Bioengineering 118(8):3239-3250. |
pharma gmp | 1 | 1.04x | Table 1 itemises the purchased cost build-up of one 20 m3 aseptic bioreactor and publishes the author's own bare-cost scaling exponent over 1-20 m3, so the figure can be moved to another volume on the source's own curve rather than on untangle's. |
| P42 - Wimble 2025 Table 4 Wimble et al. (2025) Analysis of the economic viability and environmental impacts of a conceptual process model for the recovery of lactic acid from spent media in cultivated meat production. Biotechnology Progress. |
industrial biotech | 5 | 1.14x | Table 4 breaks the 4,668,399 USD capital total into six named unit operations. It is the only paper of the 185 in TEA_refs/papers that publishes capital per unit operation. |
| P238 - Apple pomace biorefinery, Table 2 Apple Pomace Integrated Biorefinery for Biofuels Production: A Techno-Economic and Environmental Sustainability Analysis. Resources 13(11):156, 2024. |
commodity bulk | 0 | not yet in the run | Table 2 is headed 'Purchase cost of the most important units' and its columns are Section | Equipment | Value | Unit | Ceq.fob ($) | Amount | Total ($). It therefore publishes, for each named machine, BOTH the size and a per-unit purchased cost - the two things an anchor needs and the two things almost no paper prints together. Found 2026-09-04 by TEA_refs/tools/scan_per_op_capital.py over the 500-paper corpus: of 313 papers scanned it and NREL/TP-5100-47764 were the only two with five or more equipment lines carrying a name, a size and a price. |
Two published items are deliberately not compared. A mapping is only made when an untangle operation would genuinely be used for that duty; pairing a machine with an operation that does something else would manufacture agreement or disagreement out of the mapping rather than out of the cost model.
| Published item | Source | Published USD | Why it is not compared |
|---|---|---|---|
| Molecular sieve package (9 pieces, Delta-T) | NREL/TP-5100-47764 tag M-503 |
2,557,091 | untangle has no gas-phase adsorption operation. activated_carbon is a liquid-phase polishing bed and is not the same machine, so mapping it would compare two different duties. |
| Product storage | P42 - Wimble 2025 Table 4 Table 4 |
158,569 | untangle does not model product storage as a unit operation; it is carried in working capital, not in the equipment list. |
| Beer column (Megtec, 14 ft dia x 76 ft, 32 trays) | NREL/TP-5100-47764 tag D-501 |
3,350,232 | STRUCK 2026-09-03: the duty basis cannot be verified and is probably not the column's hydraulic load. NREL scales this item on stream tag strm.a500.511 at 30,379 kg/hr. The plant makes 61 MMgal/yr of ethanol, which over 8,410 h is 27,457 L/hr - within 6% of that figure. A beer column's FEED is the fermented broth at roughly 5 wt% ethanol, so its hydraulic load is more than an order of magnitude larger; 30,379 kg/hr looks like an ethanol-rich stream, not the feed. untangle's distillation entry is a FEED-FLOW correlation, so on that reading the row priced untangle's column an order of magnitude too small against a 14 ft x 76 ft, 32-tray vessel, and it was setting the Tier 1 median. Resolving it needs NREL's Area 500 stream table, which is not in the tree (papers/ is git-ignored). Separately, a column is bought by diameter - vapour load, hence reflux ratio and relative volatility - and by stage count, neither of which a feed-flow correlation can see. Found by the 2026-09-03 chemical-engineering review. |
Each row prices the same machine at the size its source quoted. Published costs are shown both as printed and escalated to a 2026 CEPCI basis, because several of these quotes are fifteen years old and comparing them raw would flatter untangle; the ratio column uses the escalated figure. The median is 1.10x, 12 of 12 land within 2.0x, and 8 within ±25%. The spread runs from 0.69x to 1.52x.
Read that median as a floor, not an estimate. Only 2 of these 12 rows compare like scope with like. 9 compare untangle’s purchased cost against a published figure that is WIDER - either a vendor turnkey price quoted at an installation factor of one, or a paper that states it applied installation factors - and 1 against one that is narrower. Those corrections do not cancel; they run the same way on nine rows. Applying only the corrections that are arithmetically exact gives 1.10x; applying judged installation factors across the rest gives a band of 1.25x to 2.26x, central 1.71x. The published 1.10x is the number nobody has to argue about, and it is the lowest of them.
| Operation | Source | Size | Published | At 2026 CEPCI | untangle | Ratio |
|---|---|---|---|---|---|---|
| nutsche filter Pressure filter (Larox, 384 m2 filtration area) |
NREL/TP-5100-47764 Appendix B mechanical equipment list, tag S-505 |
36,538 L/hr | 3,519,098 | 5,162,366 | 4,135,951 | 0.80x |
| thin film evaporator Evaporator system (wastewater concentration) |
NREL/TP-5100-47764 Appendix B mechanical equipment list, tag M-640 |
411,178 L/hr | 3,733,767 | 5,477,276 | 8,329,145 | 1.52x |
| microfiltration Membrane bioreactor (ADI, includes membrane CIP and air scour) |
NREL/TP-5100-47764 Appendix B mechanical equipment list, tag R-609 |
411,178 L/hr | 5,155,780 | 7,563,308 | 9,394,536 | 1.24x |
| reverse osmosis Reverse osmosis system (ADI) |
NREL/TP-5100-47764 Appendix B mechanical equipment list, tag S-610 |
411,178 L/hr | 2,171,816 | 3,185,961 | 3,382,077 | 1.06x |
| centrifugation disc Centrifuge (wastewater sludge dewatering) |
NREL/TP-5100-47764 Appendix B mechanical equipment list, tag S-611 |
411,178 L/hr | 6,378,482 | 9,356,960 | 13,289,490 | 1.42x |
| stirred tank bioreactor Aerobic cellulase fermenter, 80,000 gal (302.8 m3) - vessel F-400 plus agitator A-400 plus a ninth share of the M-401 air package |
NREL/TP-5100-47764 Appendix B mechanical equipment list, Area 400, tags F-400 / A-400 / M-401 |
48,000 L | 319,613 | 494,821 | 520,904 | 1.05x |
| stirred tank bioreactor Aseptic 316L stirred-tank bioreactor, 20 m3, ASME BPE-2016 |
Humbird 2021 Table 1 Table 1, purchased cost build-up |
48,000 L | 1,035,609 | 1,387,452 | 1,446,957 | 1.04x |
| microfiltration Membrane filtration |
P42 - Wimble 2025 Table 4 Table 4, Overview of capital costs for lactic acid recovery and purification |
56,196 L/hr | 2,157,464 | 2,184,774 | 2,887,579 | 1.32x |
| activated carbon Activated carbon beds |
P42 - Wimble 2025 Table 4 Table 4, Overview of capital costs for lactic acid recovery and purification |
50,576 L/hr | 293,017 | 296,726 | 351,889 | 1.19x |
| ion exchange anion Ion exchange |
P42 - Wimble 2025 Table 4 Table 4, Overview of capital costs for lactic acid recovery and purification |
50,572 L/hr | 241,155 | 244,208 | 236,173 | 0.97x |
| reverse osmosis NF / RO skid |
P42 - Wimble 2025 Table 4 Table 4, Overview of capital costs for lactic acid recovery and purification |
28,378 L/hr | 1,018,552 | 1,031,445 | 716,292 | 0.69x |
| thin film evaporator Multi-effect evaporator |
P42 - Wimble 2025 Table 4 Table 4, Overview of capital costs for lactic acid recovery and purification |
1,752 L/hr | 799,641 | 809,763 | 923,730 | 1.14x |
| stirred tank bioreactor Fermenter (ethanol fermentation, 12 off) |
P238 - Apple pomace biorefinery, Table 2 Table 2, Purchase cost of the most important units, Fermentation section |
711,100 L | 673,465 | 0 | 3,572,429 | not yet in the run |
| stirred tank bioreactor Seed reactor 3 (1 off) |
P238 - Apple pomace biorefinery, Table 2 Table 2, Purchase cost of the most important units, Fermentation section |
407,900 L | 384,188 | 0 | 2,093,202 | not yet in the run |
| stirred tank bioreactor Seed reactor 1 (3 off) |
P238 - Apple pomace biorefinery, Table 2 Table 2, Purchase cost of the most important units, Fermentation section |
27,200 L | 73,668 | 0 | 360,098 | not yet in the run |
Read down the ratio column and the pattern is not scatter, but it is not raw duty either: a bed-sized column at fifty cubic metres an hour agrees while a flow-sized membrane at the same duty does not. The split that does separate the rows is whether untangle bought one machine or a parallel train. The 9 rows served by a single unit have a median of 1.14x; the 3 served by parallel trains have a median of 0.97x, and the largest train on the page is 4 units.
Both bioreactor rows land inside ±5% - and they come from two different authors, at opposite ends of the grade ladder, on a vessel basis where both sides describe the same 48 m3 tank. 4 of the 5 rows from the one paper that publishes per-operation capital agree within ±31%, at duties between 1,752 and 56,196 L/hr. The rows that miss badly are all at commodity throughput: the national-lab wastewater train runs at 411 m3/hr, which is more than two orders of magnitude past the 1,000 L/hr point every catalogue entry is anchored at.
Microfiltration is the clearest single signal on the page. It is the one operation that 2 independent anchors both disagree with, in the same direction, at a median of 1.28x and a worst case of 1.32x - and both of those rows apply it at 41.1x its single-unit ceiling of 10,000 L/hr. That is the same defect the whole-chain benchmark records against its lactic-acid case, arrived at from a completely different direction.
Tier 1 is short because the evidence is short. Tier 2 is the opposite: every catalogue
operation, 31 of them, priced through the full thorough-mode path at
1,000 L/hr and compared to the anchor in its own database entry. All
31 sit inside the 50% house rule that
backend/tests/test_capex_vs_published.py enforces on every commit, with
0 exceptions.
That statement is worth much less than it looks, and the split below is the reason. For an operation whose price comes straight off its database anchor, agreement is true by construction: the row proves the scaling law, the id mapping and the multi-unit rule have not drifted, and it proves nothing whatever about accuracy. It is a regression guard. Only the designed-size operations - membranes sized on computed area, bind-elute columns sized on computed bed volume - are a real test, because there an independent size correlation has to land back on the anchor without being told to.
10 operations are sized from a physical quantity the simulation computes. Their median miss is 21.8% and the worst is 40.0%. This is the informative half of Tier 2.
| Operation | Anchor grade | Anchor | untangle | Miss | Anchor note |
|---|---|---|---|---|---|
| microfiltration | food grade | 260,870 | 365,340 | +40.0% | 2026 re-anchor, crossflow MF skid @1000 L/hr |
| reverse osmosis | chemical | 90,000 | 122,845 | +36.5% | 2026 re-anchor, RO learning-curve data |
| hydrophobic interaction chromatography | pharma gmp | 700,000 | 517,100 | -26.1% | 2026 re-anchor, HIC system |
| ion exchange cation | pharma gmp | 700,000 | 517,100 | -26.1% | 2026 re-anchor, GMP IEX system @1000 L/hr |
| size exclusion | pharma gmp | 650,000 | 795,777 | +22.4% | 2026 re-anchor; DB-priced (load-volume bed) |
| affinity chromatography | pharma gmp | 800,000 | 631,028 | -21.1% | 2026 re-anchor, protein-A class system |
| reverse phase | pharma gmp | 650,000 | 517,100 | -20.4% | 2026 re-anchor, prep RP system |
| ultrafiltration 10k | food grade | 391,304 | 409,683 | +4.7% | 2026 re-anchor, TFF skid @1000 L/hr |
| nanofiltration | food grade | 278,261 | 290,731 | +4.5% | corrected 2026-08-19, ~4.0k USD/m2 parity with UF |
| depth filtration | food grade | 104,348 | 104,304 | +0.0% | 2026 re-anchor, pod holder + skid @1000 L/hr |
21 operations are priced directly off their anchor. Their median miss is 0.0%, which is CEPCI rounding and the multi-unit rule, not a measurement. These rows are here so that a future change to the scaling law, the id mapping or the grade ladder shows up as a number that moved.
| Operation | Anchor grade | Anchor | untangle | Miss | Anchor note |
|---|---|---|---|---|---|
| centrifugation disc | pharma gmp | 650,000 | 936,326 | +44.1% | 2026 re-anchor, disc-stack vendor data |
| freeze drying | pharma gmp | 2,000,000 | 1,449,235 | -27.5% | one ~100 m2 lyophilizer, ~25 L/hr of fill |
| vacuum tray drying | chemical | 880,000 | 749,179 | -14.9% | one vacuum tray dryer published @max 200 L/hr |
| ultrafiltration 100k | food grade | 391,304 | 440,530 | +12.6% | existing 100 kDa cassette on the 2026 TFF skid @1000 L/hr |
| nutsche filter | chemical | 350,000 | 373,861 | +6.8% | 2026 re-anchor, agitated nutsche |
| activated carbon | chemical | 100,000 | 100,000 | +0.0% | 2026 re-anchor, GAC contactor system |
| air lift fermentor | industrial biotech | 666,000 | 666,000 | +0.0% | STR x0.8, no agitator gearbox |
| basket centrifuge | chemical | 500,000 | 500,000 | +0.0% | 2026 re-anchor, batch basket |
| continuous bioreactor | industrial biotech | 915,000 | 915,000 | +0.0% | STR x1.1 continuous premium |
| continuous heat sterilizer | chemical | 250,000 | 250,000 | +0.0% | 2026 re-anchor, HTST skid |
| crystallization | chemical | 400,000 | 400,000 | +0.0% | 2026 re-anchor, Towler class, CEPCI-escalated |
| electrodialysis | chemical | 600,000 | 600,000 | +0.0% | 2026 re-anchor, ED stack cost data |
| fed batch bioreactor | industrial biotech | 1,065,000 | 1,065,000 | +0.0% | STR x1.28 feed system premium |
| flocculation | chemical | 90,000 | 90,000 | +0.0% | 2026 re-anchor, agitated floc tank system |
| fluid bed dryer | chemical | 500,000 | 500,000 | +0.0% | 2026 re-anchor, GEA/Glatt class |
| liquid liquid extraction | chemical | 350,000 | 350,000 | +0.0% | 2026 re-anchor, mixer-settler train |
| mixing vessel | food grade | 160,000 | 160,000 | +0.0% | 2026 re-anchor, instrumented blend system |
| precipitation | chemical | 300,000 | 300,000 | +0.0% | 2026 re-anchor, reactor + dosing system |
| spray drying | pharma gmp | 600,000 | 600,000 | +0.0% | 2026 re-anchor, vendor data |
| stirred tank bioreactor | industrial biotech | 832,000 | 832,000 | +0.0% | NREL D1 + Humbird 2021, purchased scope |
| viral inactivation | pharma gmp | 180,000 | 180,000 | +0.0% | 2026 re-anchor, low-pH hold system |
Tier 2 pins every operation at exactly one duty. Real cases apply them one to three orders of magnitude away from it, and the whole-chain benchmark's largest open capital error is an operation being read 41.1x past its ceiling. So this tier takes each Tier 1 source's own published correlation - the source's exponent, the source's quoted point - and walks both curves across the range.
Two numbers frame every table below. At the 5 points where the source actually quoted a price, rather than extrapolating one, the median ratio is 1.24x. At the 1,000 L/hr calibration point, where untangle is the one not extrapolating, it is 0.94x. Neither curve is evidence away from its own anchor, and the tables mark which point is which.
Below each entry's single-unit ceiling the median ratio is 1.01x. Above it, where untangle stops buying one machine and starts buying parallel trains, it is 0.97x. The mechanism is visible in the trains column: the sources scale one machine indefinitely and untangle does not, so the two curves are guaranteed to separate, and the only question is whether the separation is physical. In the worst case on this page untangle buys 38 parallel nutsche filter units to serve 411,178 L/hr against a ceiling of 10,000 L/hr, which no engineer would specify.
| Duty L/hr | Source correlation | untangle | Ratio | Trains | |
|---|---|---|---|---|---|
| 1,000 | 147,961 | 225,000 | 1.52x | 1 | |
| 2,500 | 256,396 | 389,894 | 1.52x | 1 | |
| 5,000 | 388,623 | 590,969 | 1.52x | 1 | |
| 10,000 | 589,043 | 895,741 | 1.52x | 1 | |
| 25,000 | 1,020,730 | 1,552,196 | 1.52x | 1 | |
| 50,000 | 1,547,137 | 2,352,689 | 1.52x | 1 | |
| 100,000 | 2,345,021 | 3,566,010 | 1.52x | 1 | |
| 200,000 | 3,554,387 | 5,405,060 | 1.52x | 1 | |
| 411,178 | 5,477,276 | 8,329,145 | 1.52x | 1 | source’s quoted point |
| Duty L/hr | Source correlation | untangle | Ratio | Trains | |
|---|---|---|---|---|---|
| 1,000 | 204,312 | 187,826 | 0.92x | 1 | |
| 2,500 | 354,045 | 340,735 | 0.96x | 1 | |
| 5,000 | 536,631 | 534,671 | 1.00x | 1 | |
| 10,000 | 813,381 | 838,988 | 1.03x | 1 | |
| 25,000 | 1,409,477 | 1,522,008 | 1.08x | 1 | |
| 50,000 | 2,136,367 | 2,388,286 | 1.12x | 1 | |
| 100,000 | 3,238,127 | 3,747,623 | 1.16x | 1 | |
| 200,000 | 4,908,083 | 5,880,651 | 1.20x | 1 | |
| 411,178 | 7,563,308 | 9,394,536 | 1.24x | 1 | source’s quoted point |
| Duty L/hr | Source correlation | untangle | Ratio | Trains | |
|---|---|---|---|---|---|
| 1,000 | 290,170 | 315,000 | 1.09x | 1 | |
| 2,500 | 603,956 | 545,852 | 0.90x | 1 | |
| 5,000 | 1,051,548 | 827,356 | 0.79x | 1 | |
| 10,000 | 1,830,851 | 1,254,038 | 0.69x | 1 | |
| 25,000 | 3,810,702 | 3,021,419 | 0.79x | 3 | past the 10,000 L/hr ceiling |
| 36,538 | 5,162,366 | 4,135,951 | 0.80x | 4 | source’s quoted point |
| 50,000 | 6,634,817 | 5,338,061 | 0.81x | 5 | past the 10,000 L/hr ceiling |
| 100,000 | 11,551,888 | 9,961,175 | 0.86x | 10 | past the 10,000 L/hr ceiling |
| 200,000 | 20,113,005 | 18,304,363 | 0.91x | 19 | past the 10,000 L/hr ceiling |
| 411,178 | 35,799,492 | 34,726,703 | 0.97x | 38 | past the 10,000 L/hr ceiling |
| Duty L/hr | Source correlation | untangle | Ratio | Trains | |
|---|---|---|---|---|---|
| 1,000 | 86,064 | 81,000 | 0.94x | 1 | |
| 2,500 | 149,137 | 142,958 | 0.96x | 1 | |
| 5,000 | 226,050 | 219,708 | 0.97x | 1 | |
| 10,000 | 342,628 | 337,664 | 0.99x | 1 | |
| 25,000 | 593,727 | 595,947 | 1.00x | 1 | |
| 50,000 | 899,921 | 915,897 | 1.02x | 1 | |
| 100,000 | 1,364,026 | 1,407,619 | 1.03x | 1 | |
| 200,000 | 2,067,476 | 2,163,334 | 1.05x | 1 | |
| 411,178 | 3,185,961 | 3,382,077 | 1.06x | 1 | source’s quoted point |
| Duty L/hr | Source correlation | untangle | Ratio | Trains | |
|---|---|---|---|---|---|
| 1,000 | 252,765 | 234,000 | 0.93x | 1 | |
| 2,500 | 438,007 | 412,989 | 0.94x | 1 | |
| 5,000 | 663,894 | 634,713 | 0.96x | 1 | |
| 10,000 | 1,006,275 | 975,474 | 0.97x | 1 | |
| 25,000 | 1,743,736 | 1,721,625 | 0.99x | 1 | |
| 50,000 | 2,643,010 | 2,645,923 | 1.00x | 1 | |
| 100,000 | 4,006,054 | 4,066,454 | 1.01x | 1 | |
| 200,000 | 6,072,043 | 7,588,271 | 1.25x | 2 | past the 150,000 L/hr ceiling |
| 411,178 | 9,356,960 | 13,289,490 | 1.42x | 3 | source’s quoted point |
Every ceiling in the model, with the duty its anchor was quoted at. The headroom column is the ratio between them: how far an operation can be scaled before the multi-unit rule takes over from the exponent. It spans 1.0x to 150.0x, median 5.0x, and 8 operations reach their ceiling at no more than twice the duty they were anchored at - which means that for those, almost every real use is on the parallel-train branch rather than the scaling branch.
| Operation | Category | Anchor grade | Anchor USD | Anchored at L/hr | Exponent | Ceiling L/hr | Headroom | Tier 2 class |
|---|---|---|---|---|---|---|---|---|
| freeze drying | drying | pharma gmp | 2,000,000 | 25 | 0.5 | 25 | 1.0x | database priced |
| reverse phase | purification | pharma gmp | 650,000 | 1,000 | 0.65 | 1,000 | 1.0x | designed size |
| vacuum tray drying | drying | chemical | 880,000 | 200 | 0.55 | 200 | 1.0x | database priced |
| basket centrifuge | clarification | chemical | 500,000 | 1,000 | 0.65 | 2,000 | 2.0x | database priced |
| fluid bed dryer | drying | chemical | 500,000 | 1,000 | 0.6 | 2,000 | 2.0x | database priced |
| hydrophobic interaction chromatography | purification | pharma gmp | 700,000 | 1,000 | 0.65 | 2,000 | 2.0x | designed size |
| nanofiltration | purification | food grade | 278,261 | 1,000 | 0.7 | 2,000 | 2.0x | designed size |
| size exclusion | polishing | pharma gmp | 650,000 | 1,000 | 0.6 | 2,000 | 2.0x | designed size |
| affinity chromatography | purification | pharma gmp | 800,000 | 1,000 | 0.6 | 5,000 | 5.0x | designed size |
| air lift fermentor | upstream | industrial biotech | 666,000 | 1,000 | 0.65 | 5,000 | 5.0x | database priced |
| continuous bioreactor | upstream | industrial biotech | 915,000 | 1,000 | 0.65 | 5,000 | 5.0x | database priced |
| depth filtration | clarification | food grade | 104,348 | 1,000 | 0.6 | 5,000 | 5.0x | designed size |
| electrodialysis | purification | chemical | 600,000 | 1,000 | 0.75 | 5,000 | 5.0x | database priced |
| fed batch bioreactor | upstream | industrial biotech | 1,065,000 | 1,000 | 0.65 | 5,000 | 5.0x | database priced |
| stirred tank bioreactor | upstream | industrial biotech | 832,000 | 1,000 | 0.65 | 5,000 | 5.0x | database priced |
| ultrafiltration 100k | purification | food grade | 391,304 | 1,000 | 0.7 | 5,000 | 5.0x | database priced |
| ultrafiltration 10k | purification | food grade | 391,304 | 1,000 | 0.7 | 5,000 | 5.0x | designed size |
| activated carbon | polishing | chemical | 100,000 | 1,000 | 0.6 | 10,000 | 10.0x | database priced |
| ion exchange cation | purification | pharma gmp | 700,000 | 1,000 | 0.75 | 10,000 | 10.0x | designed size |
| microfiltration | clarification | food grade | 260,870 | 1,000 | 0.65 | 10,000 | 10.0x | designed size |
| nutsche filter | clarification | chemical | 350,000 | 1,000 | 0.6 | 10,000 | 10.0x | database priced |
| viral inactivation | polishing | pharma gmp | 180,000 | 1,000 | 0.55 | 10,000 | 10.0x | database priced |
| crystallization | purification | chemical | 400,000 | 1,000 | 0.65 | 20,000 | 20.0x | database priced |
| liquid liquid extraction | purification | chemical | 350,000 | 1,000 | 0.6 | 20,000 | 20.0x | database priced |
| reverse osmosis | purification | chemical | 90,000 | 1,000 | 0.62 | 20,000 | 20.0x | designed size |
| continuous heat sterilizer | upstream | chemical | 250,000 | 1,000 | 0.55 | 50,000 | 50.0x | database priced |
| precipitation | clarification | chemical | 300,000 | 1,000 | 0.6 | 50,000 | 50.0x | database priced |
| flocculation | clarification | chemical | 90,000 | 1,000 | 0.6 | 100,000 | 100.0x | database priced |
| mixing vessel | preparation | food grade | 160,000 | 1,000 | 0.6 | 100,000 | 100.0x | database priced |
| spray drying | drying | pharma gmp | 600,000 | 1,000 | 0.6 | 100,000 | 100.0x | database priced |
| centrifugation disc | clarification | pharma gmp | 650,000 | 1,000 | 0.62 | 150,000 | 150.0x | database priced |
A ratio says a machine is priced wrong. It does not say which of the model's three knobs is wrong, and those knobs have entirely different evidence behind them and entirely different consequences. Every Tier 1 flow-based gap splits into three terms exactly - the split below is an identity, not a regression, and the build fails if the three do not re-multiply to the measured ratio.
First, how much of each row is evidence at all. NREL publishes both the size the vendor quoted and the size the report scaled that quote to, and the second column of its appendix was being read while the first was thrown away. It matters: where the two agree, the price is a vendor quote at the duty being compared, so one package covers this duty is a procurement fact and the ceiling it implies is real. Where they disagree the report is extrapolating on its own exponent and the row says nothing about what size can be bought.
4 of the 5 rows are quoted within 10% of the duty used. Across the whole appendix it is 93 of 144 items.
| Operation | Item | Vendor quoted at L/hr | Report uses at L/hr | Scale ratio | |
|---|---|---|---|---|---|
| nutsche filter | Pressure filter (Larox, 384 m2 filtration area) |
31,815 | 36,538 | 1.15x | the report extrapolated: not evidence of procurable size |
| thin film evaporator | Evaporator system (wastewater concentration) |
393,100 | 411,178 | 1.05x | quoted at the duty compared: a procurement fact |
| microfiltration | Membrane bioreactor (ADI, includes membrane CIP and air scour) |
393,100 | 411,178 | 1.05x | quoted at the duty compared: a procurement fact |
| reverse osmosis | Reverse osmosis system (ADI) |
393,100 | 411,178 | 1.05x | quoted at the duty compared: a procurement fact |
| centrifugation disc | Centrifuge (wastewater sludge dewatering) |
393,100 | 411,178 | 1.05x | quoted at the duty compared: a procurement fact |
Now the split. LEVEL is the anchor price with the scale argument removed from both sides - untangle at its 1000 L/hr reference over the source's price carried back to 1000 L/hr on the source's exponent. EXPONENT is (duty/1000)^(e_untangle - e_source), pure disagreement about the economy of scale compounded over the whole span. TRAINS is the surcharge for buying parallel machines rather than one.
Read the three terms as a diagnostic, not as three measurements. LEVEL is defined through the source's exponent, and on these rows that exponent never acted: the vendor quoted at the duty used, so any error in it transfers one-for-one into LEVEL. Only the PRODUCT of the first two terms is measured - untangle's single-machine price at the source's own quoted duty, over the source's price there. That product averages 1.02x. The trains term, 1.16x, is the second and independent measurement. The corrected reading of this table is therefore two numbers, not three.
What survives is the direction. The level term averages 1.06x and 4 of 5 rows sit within ±25% of parity, so nothing here indicts the anchor prices; and the trains term is the largest single mechanism on the page. A row at 3x is not a mispriced machine, it is a correctly priced machine bought too many times.
| Operation | Scale span | Exponent u/src | Trains | Level | Exponent | Trains term | Total |
|---|---|---|---|---|---|---|---|
| thin film evaporator | 411x | 0.60 / 0.60 | 1 | 1.52x | 1.00x | 1.00x | 1.52x |
| centrifugation disc | 411x | 0.62 / 0.60 | 3 | 0.93x | 1.13x | 1.36x | 1.42x |
| microfiltration | 411x | 0.65 / 0.60 | 1 | 0.92x | 1.35x | 1.00x | 1.24x |
| reverse osmosis | 411x | 0.62 / 0.60 | 1 | 0.94x | 1.13x | 1.00x | 1.06x |
| nutsche filter | 36x | 0.60 / 0.80 | 4 | 1.09x | 0.49x | 1.52x | 0.80x |
The exponents themselves, as the source publishes them. This is the only per-equipment-class exponent table in the library that comes from a costing study rather than a textbook, so it is what untangle's own exponents can be set against. Median across all 144 items is 0.70.
Read it with the scale-ratio column. An item quoted at the size it is used at never exercised its exponent, so these are the report's stated conventions rather than exponents fitted from repeated quotes - a literature datum of the same kind as Towler or Peters, not a measurement. And note that adopting them means lowering untangle's, which runs against the house rule that holds exponents at the high end of their band so scale-up errs expensive. That rule is a deliberate choice, not an oversight; what the next section measures is what it costs.
| Equipment kind | Items | Exponent median | Range | Installation factor | Median scale ratio |
|---|---|---|---|---|---|
| pumps | 38 | 0.80 | 0.60 - 0.80 | 2.3 | 1.04x |
| tanks and vessels | 29 | 0.70 | 0.60 - 0.70 | 2.0 | 1.05x |
| packaged systems | 23 | 0.60 | 0.00 - 0.60 | 1.7 | 1.05x |
| agitators | 22 | 0.50 | 0.50 - 1.00 | 1.5 | 1.05x |
| reactors and fermenters | 10 | 0.85 | 0.70 - 1.00 | 1.8 | 1.00x |
| heat exchangers | 8 | 0.70 | 0.60 - 1.00 | 2.2 | 1.02x |
| conveyors | 6 | 0.60 | 0.60 - 0.80 | 1.7 | 1.10x |
| separators and filters | 5 | 0.60 | 0.60 - 0.80 | 1.7 | 1.05x |
| distillation columns | 1 | 0.60 | 0.60 - 0.60 | 2.4 | 0.96x |
One reading of the scale table is that untangle's curve should simply be fitted to the source's. It is worth taking seriously, and it fails for a specific reason.
Fit the exponent so untangle passes exactly through the point the source actually quoted - one free parameter, anchored at untangle's own reference - and ask whether the answer is a number anyone has published for that equipment class. On 4 of 5 operations it is not.
That is the argument against fitting, in one table. An exponent is a physical claim about how one machine's cost grows, and its band is set by what the machine is made of: a membrane plant is element count, near-linear; a column is diameter squared; a vessel is the six-tenths shell plus a drive that scales faster. If the only exponent that reaches the published point lies outside that band, the disagreement is not in the exponent - it is in the level, the scope or the grade - and fitting it anyway would launder a level error into a scaling law, which then makes every OTHER duty wrong. The one operation whose two-point fit lands inside its band is the one place this evidence could honestly move a curve.
| Operation | Exponent now | Exponent a two-point fit demands | Published band | |
|---|---|---|---|---|
| thin film evaporator | 0.60 | 0.530 | 0.55 - 0.70 | below the published band |
| reverse osmosis | 0.62 | 0.610 | 0.70 - 0.85 | below the published band |
| centrifugation disc | 0.62 | 0.613 | 0.60 - 0.70 | inside the published band |
| microfiltration | 0.65 | 0.614 | 0.70 - 0.85 | below the published band |
| nutsche filter | 0.60 | 0.777 | 0.55 - 0.70 | above the published band |
The obvious next question is whether adopting the source's exponents and its single-package ceilings would make the whole-chain benchmark agree better with its papers. It is measurable, so here it is measured - on that page's own statistics, each scenario applied in memory with no price touched, and every change in correlation carrying a paired bootstrap interval over 20,000 resamples of the same cases.
The answer is no.
Ceilings. The vendor-quoted package size is now shipped for the non-sanitary grades, so this scenario probes what is left: extending it to the sanitary grades as well, where the CIP-coverage argument says it should not go. Correlation on capital moves by under 0.001 either way - nothing, which is the answer that argument predicts.
The exponents no longer buy anything. On the cases every scenario can be paired on, capital correlation goes from 0.115 to 0.114, a change of -0.001 with a 95% interval of [-0.006, 0.005], which contains zero. The share within 2x goes from 14% to 14%, the median from 0.47x to 0.46x and the median spread from 3.53x to 3.53x. The 2026-09-05 measurement found a gain of about one hundredth in r here; on the current engine it is gone. The cost model has moved a long way since, with evaporator and column trains among other lines now priced on their own design, and this page does not attribute the change to any one of those moves.
Both together is the same as the exponents alone, at 0.114. Across all 4 scenarios and all three measures, 0 changes in correlation clear their own confidence interval, and that includes the least-squares price fit on the last row, the largest move on the table.
The reason is a duty mismatch, and it is the most important structural fact these two pages have produced between them. The fifteen flowsheet cases run between one and roughly a hundred times the catalogue reference. The independent anchors sit at 411 m3/hr, four hundred times it. The exponent gap and the ceiling both do their damage beyond where the benchmark cases live, so the per-equipment evidence and the whole-chain scorecard are not two views of one problem. Each has to be fixed on its own terms, and neither validates the other.
| Measure | Scenario | n | Median | Within 2x | Spread | r (log) | Change in r [95% CI] |
|---|---|---|---|---|---|---|---|
| TCI | baseline | 8 | 0.70x | 12% | 3.84x | 0.482 | |
| Vendor ceilings | 7 | 0.47x | 14% | 3.53x | 0.115 | +0.000 [+0.000, +0.000] | |
| Source exponents | 7 | 0.46x | 14% | 3.53x | 0.114 | -0.001 [-0.006, +0.005] | |
| Both together | 7 | 0.46x | 14% | 3.53x | 0.114 | -0.001 [-0.006, +0.005] | |
| Fitted prices (contrast) | 7 | 0.67x | 43% | 3.17x | 0.297 | +0.182 [-0.073, +0.553] | |
| OPEX | baseline | 6 | 0.67x | 67% | 1.76x | 0.434 | |
| Vendor ceilings | 6 | 0.67x | 67% | 1.76x | 0.434 | +0.000 [+0.000, +0.000] | |
| Source exponents | 6 | 0.67x | 67% | 1.76x | 0.434 | -0.000 [-0.004, +0.001] | |
| Both together | 6 | 0.67x | 67% | 1.76x | 0.434 | -0.000 [-0.004, +0.001] | |
| Fitted prices (contrast) | 6 | 0.68x | 83% | 1.70x | 0.494 | +0.060 [-0.033, +0.264] | |
| COGS | baseline | 7 | 0.52x | 43% | 2.14x | 0.965 | |
| Vendor ceilings | 7 | 0.52x | 43% | 2.14x | 0.965 | +0.000 [+0.000, +0.000] | |
| Source exponents | 7 | 0.52x | 43% | 2.15x | 0.965 | -0.000 [-0.002, +0.000] | |
| Both together | 7 | 0.52x | 43% | 2.15x | 0.965 | -0.000 [-0.002, +0.000] | |
| Fitted prices (contrast) | 7 | 0.54x | 43% | 2.13x | 0.969 | +0.004 [-0.001, +0.156] |
1. At the size it was calibrated for, the cost model is good. Where a published source and untangle both sit near their own anchor, agreement is inside ±25% across different authors, different equipment classes and a fifteen-year span of quote years. That is a stronger result than the whole-chain page can show, because there is no Lang factor, no battery-limit convention and no wastewater scope in between.
2. The error tracks the multi-unit rule, not the equipment class. Split Tier 1 by whether untangle bought one machine or several and the medians are 1.14x against 0.97x. Equipment class does not sort the rows and neither does the source; a single-scale calibration read far from its anchor does.
3. The parallel-train rule is where it becomes visible. Past the single-unit ceiling capital goes close to linear in flow, and the per-operation exponent stops doing any work. Several ceilings are low enough that this is the normal case rather than the exception, and at least one produces a unit count no engineer would specify.
4. Membranes at commodity scale are the largest single gap. Two independent sources, one national-lab and one peer-reviewed, disagree with the membrane anchor in the same direction at high duty. This is the same defect the whole-chain benchmark finds in its lactic-acid case; two methods reaching one conclusion is the strongest evidence on either page.
It is 12 anchors, and they are not a sample. They are every per-equipment figure in the library that could be traced to a size and a scope. They over- represent commodity wastewater duty, because that is what the one national-lab report with an itemised equipment list happens to build, and they contain no chromatography at all.
Scope is not perfectly matched on every row. Several national-lab items are quoted with an installation factor of one because the vendor price already includes installation, and the per-operation paper's figures are most likely installed rather than purchased. Both make untangle look worse than a like-for-like comparison would, so those ratios are conservative - and they are marked, not silently mixed in.
Grade is a real difference, not only an error. A sanitary bioprocess skid and a commodity wastewater package are not the same machine. Each row is priced at the grade its source was quoted at, which is the most that can be done about it, but some of every remaining gap is legitimately grade rather than calibration.
Tier 3 compares two extrapolations. Away from its own quoted point, a source's correlation is a projection, exactly as untangle's is. The tables mark the one point per curve that is a measurement. Read the rest as showing where and why two models diverge, not as showing which is right.
Tier 2 is not accuracy. 21 of its 31 rows compare the model to the number it was built from. They are on the page because a benchmark that quietly counted them as agreement would be reporting its own inputs back to itself.
Both steps are in the repository. The harness re-prices every anchor against the working tree; the builder turns the resulting CSVs into this page. A guard test in the backend suite fails when the two disagree, so a stale page cannot be committed.
cd backend && python ../TEA_refs/tools/run_unit_op_benchmark.pycd backend && python ../TEA_refs/tools/build_benchmark2_page.pyThe anchor set, with a locator and a quote for every published figure, is
TEA_refs/data/unit_op_anchors.json. The measured rows are
unit_op_capex_benchmark.csv, unit_op_capex_sweep.csv and
unit_op_capex_ceilings.csv in the same directory. The whole-chain benchmark this
page complements is at benchmark.html.