Separate Hyaluronic Acid from Glucose

Separation strategy for Hyaluronic Acid (1500 kDa) from Glucose (180 Da) using Ultrafiltration.

Recommended technique

Ultrafiltration Best Match

Separation handle: Protein concentration & buffer exchange.

Scope: 1-100 kDa MWCO. CAPEX range: $100k-$600k.

Property comparison

PropertyHyaluronic AcidGlucose
Molecular weight1500000 Da180.16 Da
Solubility (water)100000 g/L909 g/L
Charge-10
Isoelectric point
pKa3.012.28
Density1.3 g/cm³1.54 g/cm³
Diffusion coefficient1.00e-08 cm²/s6.73e-06 cm²/s
Log P-3.24

Process design walkthrough

1

Define your feed stream

Set Hyaluronic Acid and Glucose as components with their concentrations and physical properties. Use the molecule database to auto-populate properties.

2

Drop in Ultrafiltration

Connect the feed inlet, configure operating parameters (MWCO, pH, eluent, residence time as relevant), and connect the two outlets to product and waste streams.

3

Run the simulation

untangle.bio calculates outlet concentrations using mass balance and the separation function for this technique. Iterate on parameters to optimise yield vs purity.

4

Add polishing if needed

If the single step doesn't meet your purity spec, add a second separation with a complementary handle (e.g., size after charge, hydrophobicity after size).

Frequently Asked Questions

Why is Ultrafiltration the right choice for this pair?

Ultrafiltration exploits protein concentration & buffer exchange as the separation handle. The property gap between Hyaluronic Acid and Glucose on this axis is large enough to give a clean separation in a single step at industrially relevant flow rates.

What yield and purity can I expect?

Typical single-step recovery is 85-99% depending on operating conditions. Purity from a single ultrafiltration step is in the 90-99% range; polishing steps push above 99.5%.

What does this step cost to operate?

Capital cost for Ultrafiltration at biotech scale is in the $100k-$600k range. Operating cost depends on scale, feed concentration, and product value. See the technique page for details.

How do I design this in untangle.bio?

Drop a ultrafiltration unit operation into the flowsheet, connect the feed stream containing both Hyaluronic Acid and Glucose, and the simulator will calculate mass balance and expected outlet concentrations using the molecule database properties.

Design this separation in untangle.bio

Build a flowsheet, simulate yield and purity, and estimate CAPEX for separating Hyaluronic Acid from Glucose.

Open untangle.bio

Related pages

Read more