The whole-chain benchmark scores fifteen flowsheets against the totals their sources publish. The per-operation benchmark scores single machines against published equipment prices. Both leave one question open, and it is the one that decides whether the cost catalogue is worth working on: if the catalogue were free to move, how much closer could the plants get?
That question cannot be answered by arguing. It can only be answered by moving the
catalogue and looking. So the fit below is deliberate and its result is deliberately not a
proposal - a multiplier that came out of least squares against
4 published capital totals carries no provenance, and every other number in
backend/data/unit_operation_costs.json carries a source. Dropping a fitted
value in would break that contract silently, and would make the benchmark that scored it
self-validating.
The fit targets one quantity: total capital investment on the whole-plant cases. DSP-only cases are excluded from the fit, because their published totals cover a fermentation section their flowsheets do not build - that gap is scope, not price, and fitting cost values to close it would make every other case pay for an error that is not in the catalogue. Those cases still appear below, as the cases the fit was not aimed at.
Before fitting anything, where the money is. This is every capital line across the 9 whole-plant cases, and it sets the ceiling on what any per-operation change can do: fed batch bioreactor alone is 53.9% of the purchased equipment, and the top three lines are 74% between them.
It also sets a limit the fit cannot cross. Only 85% of purchased capital is priced off a base cost a multiplier can reach at all. Packed chromatography columns come off a shared bed-volume anchor, GMP support equipment is taken as a fraction of process equipment cost, and the wastewater plant is an OSBL correlation - none of them move when a catalogue entry does.
| Unit operation | Purchased capital, all whole-plant cases | Share | In cases |
|---|---|---|---|
| fed batch bioreactor | 67,480,301 | 53.9% | 6 |
| centrifugation disc | 13,213,383 | 10.6% | 6 |
| wastewater treatment | 11,888,999 | 9.5% | 6 |
| crystallization | 9,865,363 | 7.9% | 3 |
| thin film evaporator | 7,002,488 | 5.6% | 3 |
| ultrafiltration 10k | 4,129,653 | 3.3% | 1 |
| fluid bed dryer | 2,414,137 | 1.9% | 2 |
| basket centrifuge | 2,182,860 | 1.7% | 2 |
| rna reduction heat shock | 1,936,126 | 1.5% | 1 |
| microfiltration | 1,180,451 | 0.9% | 1 |
| liquid liquid extraction | 1,082,215 | 0.9% | 1 |
| rotary dryer | 587,843 | 0.5% | 1 |
The capital chain is exactly affine in purchased equipment - the committed run reproduces it to better than a hundredth of a percent - so the response of every case to a set of multipliers can be computed from two real harness runs, one at 0.70x and one at 1.30x the whole catalogue. Fits are done on that surrogate and the winner is then re-run for real, which is the run tabulated further down.
Baseline error across the 4 fitted anchors is 0.848 in log space.
Fit A, one global multiplier. The single best scaling of the entire catalogue is x0.718. It takes the error to 0.817 - an improvement of 4%. One number cannot do more than that.
Fit B, one multiplier per equipment class, ridge-regularised at 0.050 so a class is only moved when the data pays for it. Six free parameters against 4 equations takes the error to 0.615, an improvement of 27%.
Fit B is the scenario that was re-run for real. Read the multipliers, not the error: the fit wants classes moved in opposite directions by a factor of 6.8x - from x0.43 to x2.88 - and it pushes 3 of the 12 entries it touches outside the price range those entries themselves declare. A distillation column and an evaporator are neighbouring separation equipment bought from overlapping vendor lists; a model that needs one at a third of its anchor and the other at more than double it is not describing prices.
| Equipment class | Fitted multiplier | Entries | Plausibility against the entry's own range |
|---|---|---|---|
| Solids handling and drying | x2.875 | 4 | crystallization: 400,000 → 1,150,020, ABOVE the declared range (120k - 800k depending on cooling capacity) fluid_bed_drying: 500,000 → 1,437,525, ABOVE the declared range (150k - 800k) |
| Centrifuges | x1.258 | 2 | every entry stays inside its declared range |
| Membranes | x1.110 | 3 | every entry stays inside its declared range |
| Evaporators | x1.000 | 1 | every entry stays inside its declared range |
| Distillation and reactive columns | x1.000 | 1 | every entry stays inside its declared range |
| Bioreactors and seed trains | x0.426 | 1 | fed_batch_bioreactor: 1,065,000 → 453,285, BELOW the declared range (500k - 3M depending on scale) |
This is the table that settles the question. Each case is asked what single multiplier on the reachable catalogue would put it on its own paper, ignoring the others.
Of the ones a multiplier can satisfy at all, the demands run from x0.390 to x2.804 - a spread of 7.2x. There is no catalogue that satisfies them, because they point in opposite directions: the same equipment classes, at the same facility grade, are asked to be cheaper for one plant and dearer for another. (The full column below spans 280.4x, but its low end is the search bound rather than a solution - that case has no solution, which is the next paragraph.)
1 of them cannot be satisfied at any multiplier whatsoever. The floor column is that case's total capital investment if every reachable piece of equipment were free - the wastewater plant, the unreachable equipment, the working capital and the start-up cost that remain. Where that floor is already above the paper, no cost catalogue reaches it: butyric still stands at 2.41x its published capital with the equipment given away.
| Case | TCI now | Reachable | Multiplier it needs alone | Floor if equipment were free | |
|---|---|---|---|---|---|
| butyric | 3.53x | 31% | x0.010 | 2.41x | unreachable at any multiplier |
| isobutanol | 2.31x | 97% | x0.390 | 0.16x | - |
| mycoprotein | 0.93x | 89% | x1.096 | 0.18x | - |
| succinic_stover | 0.47x | 74% | x2.804 | 0.17x | - |
Fit B applied for real, every case re-run end to end. First the anchors the fit was aimed at - whole-plant total capital investment.
| Case and anchor | Measure | Scope | Baseline | Fitted | Movement |
|---|---|---|---|---|---|
| butyric tci usd |
TCI | whole plant | 3.53x | 3.17x | closer 9% |
| isobutanol tci usd |
TCI | whole plant | 2.31x | 1.27x | closer 71% |
| mycoprotein capital usd |
TCI | whole plant | 0.93x | 0.75x | off parity |
| succinic_stover tci usd |
TCI | whole plant | 0.47x | 0.67x | closer 48% |
On the target the fit works, and it works about as well as six free parameters against 4 equations should. Mean absolute log error falls from 0.733 to 0.521 and the count inside 2x goes from 1 to 3 of 4. That is a real improvement and it is the whole of what tuning capital costs can buy.
Note what it did not buy. Even at its own optimum, on the cases it was fitted to, the fit leaves capital ratios that still span both sides of the paper. The residual is not a tuning failure - the previous table showed it is a floor.
Now every anchor the fit was not aimed at: operating cost, cost of goods, minimum selling price, and the DSP-only cases. 18 anchors, and this is the bill.
The fit moves 4 of them away from their sources. Mean absolute log error across them barely moves, 1.076 to 1.003, and on the DSP-only cases it gets worse, 1.196 to 1.162.
The headline count is positive and small: across all 22 anchors the number inside 2x goes from 9 to 12. Read how it was bought. The fit brings 4 anchors inside 2x and breaks 1 that were already inside it - and the ones it breaks are the ones that were closest to their sources to begin with, including a case that sat at near-exact parity on capital before the fit touched it. Tuning to 4 capital totals is not an improvement paid for out of slack; it is a transfer.
| Case and anchor | Measure | Scope | Baseline | Fitted | Movement |
|---|---|---|---|---|---|
| bdo unit cost usd per kg |
COGS | dsp only | 1.76x | 1.79x | further 3% |
| bdo msp usd per kg |
MSP | dsp only | 1.19x | 1.22x | further 14% |
| bdo annual opex usd |
OPEX | dsp only | 1.75x | 1.78x | further 3% |
| crude_enzyme levelised usd per kg |
COGS | dsp only | 0.07x | 0.08x | closer 2% |
| crude_enzyme annual opex usd |
OPEX | dsp only | 0.09x | 0.10x | closer 3% |
| crude_enzyme tci usd |
TCI | dsp only | 0.20x | 0.24x | closer 11% |
| isobutanol unit cost usd per kg |
COGS | whole plant | 2.82x | 2.30x | closer 20% |
| isobutanol msp usd per kg |
MSP | whole plant | 3.32x | 2.46x | closer 25% |
| isobutanol annual opex usd |
OPEX | whole plant | 1.77x | 1.45x | closer 35% |
| mab dsp cost usd per kg |
COGS | dsp only | 0.74x | 0.74x | closer 1% |
| mab dsp opex usd |
OPEX | dsp only | 0.74x | 0.74x | closer 1% |
| mab tci usd |
TCI | dsp only | 0.05x | 0.05x | closer 1% |
| mycoprotein production cost usd per kg dry basis |
COGS | whole plant | 0.52x | 0.47x | further 16% |
| plant_mab cogs usd per kg |
COGS | dsp only | 0.38x | 0.39x | closer 2% |
| plant_mab dsp opex usd |
OPEX | dsp only | 0.60x | 0.62x | closer 5% |
| plant_mab tci usd |
TCI | dsp only | 0.24x | 0.26x | closer 6% |
| succinic_stover unit cost usd per kg |
COGS | whole plant | 0.47x | 0.54x | closer 20% |
| succinic_stover annual opex usd |
OPEX | whole plant | 0.45x | 0.53x | closer 19% |
1. Per-operation capital cost is not where the whole-chain error lives. The single best global multiplier removes 4% of the error and six free class multipliers remove 27%. A model whose problem was its price list would not behave like that.
2. The cases contradict each other. The ones with a solution demand multipliers spanning 7.2x on the same equipment at the same grade. No catalogue satisfies them, so the residual after fitting is a floor and not a target.
3. Some gaps are closed to capital entirely. 1 case cannot reach its published capital even with every reachable machine free. Whatever that gap is - scope, the wastewater plant the paper takes a credit for, or the paper's own figure - it is not a price.
4. The fitted prices are not prices. 3 of 12 fitted entries land outside the vendor range recorded on the entry itself, and the fit pulls neighbouring separation equipment 6.8x apart. A catalogue that fits the benchmark stops describing the market.
5. What fitting buys is a transfer, not a gain. It improves the 4 anchors it targets and moves 4 others away, breaking 1 that were already inside 2x to bring 4 in. That is the whole return on abandoning provenance, and it is why the fitted values stay in memory.
The place to spend effort, on this evidence, is the comparison and the flowsheets rather than the price list: scope alignment on the DSP-only cases, the wastewater plant that most sources do not build, and per-equipment anchors independent enough to move a catalogue entry honestly - which is what benchmark2.html is for, and why it has so few rows.
Four steps, all in the repository. The two calibration runs give the surrogate its response, the fit solves it, and the last run applies the winner end to end. Nothing here writes to the cost database.
cd backend && python ../TEA_refs/tools/run_fitted_benchmark.py --global 0.70 --tag g070cd backend && python ../TEA_refs/tools/run_fitted_benchmark.py --global 1.30 --tag g130cd backend && python ../TEA_refs/tools/fit_capex_scenario.pycd backend && python ../TEA_refs/tools/run_fitted_benchmark.py --scenario ../TEA_refs/data/capex_fit_scenario.json --tag fittedcd backend && python ../TEA_refs/tools/build_benchmark3_page.pyThe fitted multipliers and the full fit report are
TEA_refs/data/capex_fit_scenario.json and
capex_fit_report.json. The unfitted benchmark this page is measured against is
benchmark.html; the per-equipment evidence that can move a
catalogue entry honestly is benchmark2.html.